Drag
img not found

FIRE ALARM SYSTEM PANEL

FIRE ALARM SYSTEM PANEL

Mishaps caused by fire can respond in serious injury and damage to particular property. India also has a record of fire incidents. The Uphaar Cinema fire in Delhi was one of the worst fire tragedies in recent Indian history. The fire started on Friday, 13 June 1997 at Uphaar Cinema in Green Park, Delhi during the threeo'clock webbing of the movie Border. Fifty- nine people were trapped outside and failed of asphyxiation, while 103 were seriously injured in the performing rush( suffocation). Numerous similar fire incidents small & huge situations- do every day far and wide. A many days agone , Twenty- seven people failed after a massive fire broke out at an office structure in Mundka in Delhi. Safeguarding Homes, Properties & Premises against similar unfortunate fire incidents have come an essential need of the day. Installing a fire safety system is one of the most intelligent measures you can take to manage your fire threat. Mafcon Devices manufactures accessible Fire Alarm Panels, Fire Suppression systems & Fire Alarm systems. we believe in saving the lives of every individual because every individual is a whole world for his entire family.

2/4 Zone Fire Alarm panel

The MD-02/04 series 2/4 Zone conventional fire alarm panel designed based on ETL standard. and it is the central part of a conventional fire alarm system, designed for applications requiring smoke detectors, bet, manual pull station, and sprinkler supervision. each zone can be displayed by a button

Product Features

AC INPUT 220VAC 50/60Hz
DC OUTPUT 24VDC typical
Voltage for MCU 5V for MCU
Current at 24VDC from PSE 450mA standby current
Maximum current from PSE 1A except batteries charge 1.85A maximum, current limited
Batteries current 24VDC +/- 10%, 100 mA max, current limited, monitored
Auxiliary output 2*12V/ 2.3Ah sealed lead acid gel,
Batteries self-regulated
Battery low-voltage protection 21V
Detectors connection allowed each zone 20 (except MCPs)
Zone alarm current 6mA minimum/ 27mA maximum
Sounder output 2*0.75A maximum
Fire Relay 1A/30VDC maximum
Fault Relay 1A/30VDC maximum
Communication protocol 2 wires RS485 bus system
EOL resistor for zone 4.7K 0.25W
EOL resistor for outputs 4.7K 0.25W
Fuse for AC Power 1 A/ 250V glass tube fuse 5 X 20mm
Fuse on DC Power 1A/250V glass tube fuse 5 X 20mm
Class A temperature range : -5 to
Environmental Humidity : 5 to 95% RH, non-condensing
Terminal blocks rating (0.75 to 2.5 mm2)